Mitral valve prolapse is a condition in which the valve located between the two chambers on the left side of the heart bends and bulges backward during contraction. This structural difference, also commonly known as heart valve prolapse, results from a loss of stability in the mechanism that ensures blood flows regularly in one direction.
The inability of the valve leaflets to meet edge to edge and close completely directly affects the heart’s natural working dynamics. This condition often progresses silently for many years, but when leakage becomes pronounced, it can lead to rhythm irregularities and an additional workload on the heart muscle, creating conditions for symptoms that restrict daily life.
To maintain cardiovascular health, it is vital to determine the degree of valve prolapse through precise measurements. Early diagnosis and regular cardiological monitoring help preserve the heart’s mechanical balance and prevent structural fatigue that may develop in the future.
What Structural Changes Does Mitral Valve Prolapse Cause in Our Heart?
We can compare the heart to a four-chambered house that works continuously to deliver oxygenated blood to every corner of our body. Blood oxygenated in the lungs reaches the upper left chamber of the heart and then moves toward the lower left chamber, which contains the main muscular pumping power. The mitral valve is the gateway between these two main chambers. This valve consists of a sturdy framework, two leaflets that can open and close, cords that hold these leaflets like the cables of a bridge, and projections of the heart muscle to which these cords are attached. With every heartbeat, this double-leaflet gate opens, allowing blood to flow downward. When the heart subsequently contracts, the gate closes tightly to prevent blood from returning to where it came from.
In individuals with mitral valve prolapse, however, there is physical looseness in the hinges of this gate or in the cord-like structures holding it in place. When the heart contracts and forcefully pushes blood toward the major arteries, the valve leaflets cannot withstand this high pressure. The cord-like structures may gradually stretch more than necessary, or the valve tissue itself may become softer and more flexible than normal. As a result, the leaflets bend backward and extend beyond the closure line.
This degree of bending usually begins on a very small scale and does not affect the person’s life. However, if deterioration of the valve tissue increases over the years, it becomes progressively more difficult for the leaflets to meet edge to edge and close tightly. With each heartbeat, a certain amount of blood begins to leak backward through the narrow gap that cannot close. To deliver sufficient blood to the organs, the heart must compensate for this backward-flowing blood and begins working harder than before. Over time, this mechanical problem can trigger a process that may contribute to cardiac fatigue and gradual enlargement of the heart chambers. The condition does not progress at the same rate in everyone; in some individuals it remains stable throughout life, while in others it may change in ways that require closer monitoring.
Which Genetic Factors Play a Role in the Development of Mitral Valve Prolapse?
The underlying cause of this bending and change in the shape of the heart valve is generally hereditary, meaning genetic characteristics inherited from the family. When tissue samples are examined in a laboratory, two main structural patterns are observed that explain why the valve prolapses. The first, more commonly seen in young and middle-aged individuals, involves excessive thickening of the valve tissue itself, causing it to develop a spongy consistency. The components of connective tissue that provide strength and firmness to the valve lose their organization, and the valve takes on a much more flexible and loose structure than normal.
The second condition occurs with advancing age and involves thinning of the tissue and weakening of the supporting structures. Here, rather than thickening, the valve becomes progressively thinner and more translucent, while the filaments holding it in place deteriorate and weaken. These cords, which can no longer withstand tension, may become more prone to rupture over time. The characteristics of connective tissue formation encoded in our genetic makeup play a role in both conditions. If one family member has this type of valve flexibility, the likelihood of observing a similar structure in other family members may increase with age.
Small differences in the genes that determine how our cells respond to pressure and mechanical stress inside the heart directly affect the lifespan of the heart valve. In addition, certain disorders involving connective tissue throughout the entire body, rather than just the heart, can indirectly affect the heart and cause this valve prolapse.
Some genetic connective tissue diseases that may predispose individuals to this condition include:
- Marfan syndrome
- Ehlers-Danlos syndrome
- Loeys-Dietz syndrome
- Osteogenesis imperfecta
What Symptoms May Occur in Patients with Mitral Valve Prolapse?
Many people with this condition can live completely healthy lives without ever realizing that their hearts have such a structural difference. If the degree of valve bending is mild and does not cause backward blood leakage, the heart can easily compensate for the condition. For this reason, the diagnosis is often made incidentally when a person visits the hospital for another complaint or when an unusual sound is heard while listening to the heart with a stethoscope during a routine examination. A subtle clicking sound produced by the bending valve as the heart contracts, followed immediately by a murmur, is particularly characteristic.
When the valve prolapse becomes more pronounced and the workload on the heart begins to increase, individuals start experiencing various discomforts that affect their daily lives. Mechanical tension inside the heart may trigger electrical impulses that cause irregular beats outside the heart’s normal rhythm. This is most commonly experienced as palpitations. People frequently describe feeling as though their heart stops for a moment and then beats forcefully again, or as though there is fluttering inside their chest. Sometimes these palpitations may be accompanied by sudden, stabbing chest pains that are completely unrelated to physical fatigue.
When the amount of blood leaking backward increases because the valve cannot close completely, physical signs indicating that the heart is becoming strained begin to appear. As blood returning from the lungs starts to accumulate in the heart, the respiratory system is also affected. A person may find it difficult to climb stairs that they previously climbed with ease.
The symptoms most frequently reported by patients include:
- Palpitations
- Chest pain
- Shortness of breath
- Rapid fatigue
- Sensation of skipped heartbeats
- Dizziness
- Feeling faint
Can Arrhythmogenic Mitral Valve Prolapse Cause Dangerous Heart Rhythm Problems?
Although the bending of the mitral valve was largely regarded as a mechanical problem for many years, it is now better understood that this condition can also closely affect the heart’s electrical system in some patients. Every time the valve prolapses toward the upper chamber, sudden tension and a strong pulling force develop in the cords holding the valve and at the base of the heart muscle where these cords attach. Considering that the average person’s heart beats thousands of times a day, it becomes easier to understand how continuously this small area is exposed to mechanical stress.
Continuous pulling and stretching movements can cause microscopic injuries to the heart muscle over time. As the body attempts to repair these injuries, small scars or fibrotic tissues form in the affected region. The heart muscle has a network that must transmit electrical impulses smoothly and without interruption. However, these newly formed small scars can obstruct electrical pathways, leading to irregular conduction or electrical short circuits.
These short circuits may disrupt the heart’s normal functioning, creating conditions for consecutive extra beats or an excessively rapid heartbeat. It may be beneficial to examine this mechanism more carefully, particularly in individuals with a family history of unexplained fainting at a young age or heart rhythm problems. Of course, not every patient develops these scar tissues or experiences rhythm disturbances. However, individuals with marked thickening and pronounced prolapse of both valve leaflets should be monitored more carefully for the possibility of rhythm irregularities.
Which Methods Are Used to Diagnose Mitral Valve Prolapse and Assess Its Risks?
To understand the exact condition of the disease, observe the valve structure, and predict the heart’s future performance, it is extremely important to evaluate the heart’s internal structure clearly. The diagnostic process generally begins with a standard ultrasound examination performed through the chest wall, known as echocardiography. This device uses harmless sound waves to obtain moving images of the heart in real time. The thickness of the valve leaflets, how far they bend, how much blood leaks backward through the valve, and whether the heart has enlarged in response to this mechanical condition can easily be measured using this painless method.
If the condition is somewhat more complicated, the amount of blood leakage cannot be determined, or the valve problem requires more detailed analysis, transesophageal echocardiography may be preferred. This examination is performed using a thin ultrasound probe passed through the esophagus. During the procedure, the patient’s throat is numbed and a very thin device is swallowed. High-resolution images of the valve can be obtained from directly behind the heart without any intervening bone obstruction. The location of looseness in the valve is determined with millimeter-level precision.
In addition, advanced imaging and monitoring methods may be necessary to detect cellular damage in the heart and assess the risks of rhythm disturbances.
The main diagnostic methods used in the evaluation include:
- Transthoracic echocardiography
- Transesophageal echocardiography
- Cardiac magnetic resonance imaging
- Holter rhythm monitor
- Exercise ECG test
How Does the Follow-Up Process Work After a Diagnosis of Mitral Valve Prolapse?
The most critical step after diagnosis is to establish a monitoring plan suited to the patient’s valve condition and heart capacity. Since each individual’s anatomy, valve tissue, and physiological cardiac response are different, follow-up intervals are also determined individually. Generally, no restrictive rules are imposed on someone who has only mild valve bending, no significant backward blood leakage, and no complaints in daily life. These individuals can carry out their daily activities and continue participating in sports. As long as they do not develop new symptoms, a brief ultrasound examination every few years may often be sufficient.
When the condition becomes more pronounced, meaning moderate backward leakage through the valve is detected, the aim is to shorten the follow-up intervals even if the heart has not yet enlarged. At this stage, more frequent examinations are scheduled to observe how the heart responds to the increased blood volume.
However, if the leakage through the valve has become severe, weakening or a tendency toward rupture is observed in the cords supporting the valve, or the heart has begun to enlarge in response to its continuously increased workload, much closer monitoring is required even if the patient feels well. At this stage, the heart may be approaching the limits of its endurance, and planning a structural intervention may become necessary.
The main medical parameters monitored during regular follow-up include:
- Progression of symptoms
- Valve thickness
- Severity of leakage
- Heart size
- Heart rhythm regularity
- Pulmonary blood pressure
- Functional capacity
Can Medication Alone Resolve Mitral Valve Prolapse?
When patients receive their diagnosis, they may hope that prescribed medications will correct the prolapse of their heart valve or restore worn and thinned valve tissue to its previous firm condition. However, mitral valve prolapse is a structural disorder fundamentally involving biomechanical and physical weakness of the tissue. Just as a worn window handle at home or an elastic cord that has stretched over time cannot be restored to its original condition simply by applying a solution, a prolapsed valve cannot physically regain its former structure merely by taking medication.
The primary purpose of medications in this disease is to alleviate unpleasant symptoms that make daily life difficult and to help balance the heart’s workload to some extent. Heart-rate-slowing medications can be particularly beneficial for patients who experience constant palpitations during the day, feel anxious because their hearts beat too rapidly, or suffer from rhythm irregularities. These medications regulate the rate of heart contractions, somewhat reducing the sudden mechanical pressure placed on the valve.
During periods when blood leakage progresses over the years and the heart shows a tendency to enlarge, various vasodilator or diuretic medications may be used to reduce vascular resistance against which the heart pumps or remove excess fluid accumulated in the body. However, these medications do not repair the structural valve abnormality. They only relieve the discomfort caused by the disease and aim to preserve the patient’s overall quality of life. When the heart can no longer cope with the increasing burden of leakage on its own, mechanical repair methods become more prominent.
What Is the Nonsurgical Clipping Procedure in the Treatment of Mitral Valve Prolapse?
For many years, when mechanical leakage through the valve progressed, caused difficulties for the patient, and began to strain the heart structurally, the most common method was surgery involving opening the chest. In conventional surgery, the heart was stopped, the patient was connected to a heart-lung machine, and the valve was either surgically repaired or replaced with an artificial valve. Although this traditional surgical method remains valid today, technological advances in medicine have made it possible to offer patients much less traumatic options for valve repair without open surgery.
The method medically known as transcatheter edge-to-edge repair, commonly referred to as the clipping procedure, is one of the innovative approaches in this field. This procedure aims to repair valve leakage by advancing through the blood vessels without cutting the breastbone or stopping the heart. It is performed in a fully equipped laboratory under the guidance of advanced imaging devices.
The procedure begins with a very small entry through a large blood vessel in the groin region. Thin, flexible tubes are inserted into the vessel and advanced to the right side of the heart, after which a thin membrane is gently crossed to reach the area directly above the problematic mitral valve. The small clip system at the tip of the tube is aligned with the prolapsing portion of the valve that does not close completely. While the heart continues beating and pumping blood, this clip is lowered between the valve leaflets, and the backward-prolapsing leaflets are attached to each other. When the clip is closed, two small openings joined at the center are created instead of one wide opening, substantially preventing backward blood flow. Patients can generally return to their daily routines within a short period.
Who Is Suitable for the Nonsurgical Clipping Procedure Among Patients with Mitral Valve Prolapse?
The clipping procedure performed through the groin provides a particularly valuable alternative for patients who cannot tolerate conventional open surgery or who face high surgical risks. Elderly individuals, people with chronic conditions, and patients who have previously undergone heart surgery are considered more vulnerable to open surgery. These individuals, whose physical resilience is lower, may experience difficulties overcoming the demanding recovery period following open surgery. Therefore, the clipping procedure is considered a priority option for repairing severe valve leakage in this group of patients.
With new developments in medicine, this treatment may now also be considered for certain patients with marked structural enlargement of the heart, rather than exclusively for elderly or high-risk individuals. If leakage through a person’s valve has begun to strain the heart, a clipping procedure may be planned before permanent damage develops. Of course, not every patient’s valve anatomy is suitable for this system. Before the procedure, the valve structure, leaflet thickness, and distance between the leaflets must be examined in great detail using ultrasound. Specialist medical boards perform their evaluations based on these measurements.
Some patient profiles that may be considered suitable for the procedure include:
- Elderly individuals
- People with high surgical risk
- People with chronic kidney disease
- Patients with chronic lung disease
- People who have previously undergone heart surgery
How Is Ablation Performed for Heart Rhythm Disorders Caused by Mitral Valve Prolapse?
In the advanced stages of the disease, severe palpitations and rhythm disturbances caused by continuous stretching of the heart muscle may negatively affect the patient’s quality of life, in addition to backward blood leakage through the valve. If the heart rhythm cannot be regulated despite prescribed medications, sensations of skipped heartbeats increase at unexpected moments, or episodes of excessively rapid heartbeats occur, a nonsurgical treatment method known as electrophysiological ablation may be considered.
During the procedure, special thin wires capable of measuring electrical currents are introduced into the heart through a blood vessel in the groin. Advanced computer systems are used to create a detailed electrical map of the heart’s inner walls. Areas of the heart muscle that have become irritated due to the valve’s continuous pulling and that generate irregular electrical signals are identified with millimeter-level precision.
Energy delivered through the tip of the system is then used to gently heat and precisely deactivate the small problematic area. The aim is to prevent unwanted electrical short circuits originating from that region. This procedure may help improve quality of life by substantially reducing the exhausting and uncomfortable fluttering sensation in the patient’s heart. All these modern approaches have made conditions that were previously difficult to treat more manageable today. With regular medical checkups and appropriate measures taken at the right time, patients can protect their health with confidence.

Prof. Dr. Kadriye Orta Kılıçkesmez is one of the leading figures in the field of Turkish cardiology. She was born on January 24, 1974, in Tekirdağ. After completing her undergraduate education at Istanbul University Cerrahpaşa Faculty of Medicine, she chose cardiology as her specialty and received her specialist training at the Cardiology Institute of the same university. In 2015, she was appointed by the university to establish the Şişli Etfal cardiology clinic and Angio laboratory. Becoming a professor in 2017, Kadriye Kılıçkesmez established the cardiology clinic and Angio laboratory of Prof. Dr. Cemil Taşçı Hospital in 2020 and ensured that the clinic became a training clinic.
