The aortic valve is a vital control gateway located at the heart’s main outlet; the primary function of the aortic valve is to ensure that oxygenated blood flows in one direction from the heart to the body and to prevent blood from flowing backward.

The anatomy of the aortic valve consists of a thin yet highly durable and flexible tissue structure that can readily adapt to the high-pressure changes occurring with each heartbeat.

This rhythmic opening and closing cycle, repeated approximately one hundred thousand times a day, directly contributes to the regular blood supply of all organs, particularly the brain, and to maintaining systemic blood pressure balance.

The healthy functioning of this dynamic structure, located at the starting point of the circulatory system, or its support through modern interventional cardiology techniques when it deteriorates over time, is of great importance for maintaining overall cardiac performance for many years.

What Is the Anatomy of the Aortic Valve and Where Is It Located in the Heart?

The human heart is a powerful pumping system that works continuously, day and night, and the left ventricle carries the heaviest workload in this system. The aortic valve is located between the outflow tract of the left ventricle and the ascending aorta, which marks the beginning of systemic arterial circulation. Thanks to this position, it forms the boundary between the high-pressure chamber inside the heart and the body’s main vascular network. From a medical perspective, this structure is not regarded as an isolated valve plane standing on its own but as the center of a three-dimensional, mobile anatomical unit known as the aortic root.

The main anatomical structures forming the aortic root are:

  • Aortic annulus (valve ring)
  • Semilunar leaflets (cusps)
  • Interleaflet triangular areas
  • Sinuses of Valsalva (vascular pockets)
  • Sinotubular junction

Contrary to common belief, the annulus forming the base of the valve is not a flat, circular ring; it has the appearance of a three-peaked crown following the attachment lines of the leaflets to the heart muscle and fibrous skeleton. In interventional cardiology procedures, however, the elliptical virtual plane obtained by connecting the lowest attachment points of these three leaflets is used as the reference. Immediately above this annular plane are three pocket-like cavities, known as the sinuses of Valsalva, formed by the slight outward expansion of the aortic wall. The transition line where these pockets end and the aorta assumes its normal tubular shape is called the sinotubular junction.

What Are the Main Components of a Healthy Aortic Valve Structure?

A normally developed aortic valve consists of three symmetrically positioned, crescent-shaped leaflets. These leaflets, medically referred to as cusps or leaflets, are named according to the openings of the nearby coronary arteries that supply blood to the heart muscle itself. The leaflet adjacent to the right coronary artery is called the right coronary cusp, the leaflet adjacent to the left coronary artery is called the left coronary cusp, and the third leaflet, which has no coronary artery opening, is called the non-coronary cusp.

The tissue components and anatomical structures that provide flexibility and durability to the leaflets include:

  • Collagen fibers
  • Elastin proteins
  • Proteoglycan tissue matrix
  • Lunula contact surface
  • Nodule of Arantius

Each leaflet has a thin, flexible, three-layered connective tissue architecture rich in extracellular matrix. While collagen fibers provide structural strength, elastin proteins help the valve stretch with each heartbeat and return to its original shape. The thin, crescent-shaped contact area extending along the free edges of the leaflets is called the lunula. The small tissue thickening located at the midpoint of the free edge, which supports the leaflets in opening smoothly during systole and meeting evenly at the center during diastole, is known as the nodule of Arantius.

Why Are the Tissues Surrounding the Aortic Valve and the Heart’s Electrical System Important?

The close anatomical relationship between the aortic root and other structures within the heart plays a decisive role, particularly in the safety of catheter-based treatments performed by interventional cardiologists. The tissues inside the heart are not independent of one another; they rest on a strong, continuous fibrous skeleton. The fibrous junction between the left and non-coronary leaflets of the aortic valve is anatomically continuous with the anterior leaflet of another important heart valve, the mitral valve. Because of this structure, known as the aortomitral fibrous continuity, calcification or intervention involving one valve is closely related to the function of the other valve.

In addition, the base of the junction between the non-coronary leaflet and the right coronary leaflet lies very close to the membranous septum, a membrane-like structure separating the chambers of the heart. The electrical conduction fibers that transmit the heart’s natural rhythm and contraction signals, together with the bundle of His, follow the lower edge of this membranous region and reach the inner surface of the left ventricle. This anatomical proximity explains why the implantation depth of a prosthetic valve is a critical variable in catheter-based valve interventions. Since placing the new valve too deeply toward the left ventricular outflow tract may exert pressure on these conduction fibers, measurements of this region are performed with great precision before the procedure.

How Does the Aortic Valve Function During the Cardiac Cycle?

The primary physiological function of the aortic valve is to respond passively to pressure differences between the left ventricle and the aorta throughout the cardiac cycle, allowing blood to be pumped into the body with low resistance while preventing blood from flowing back into the left ventricle during relaxation. When the heart begins to contract, pressure inside the left ventricle rises rapidly without a change in volume. As soon as left ventricular pressure exceeds the diastolic pressure inside the aorta, the valve leaflets open passively under the influence of the pressure difference, and blood is ejected into the body.

The main physiological events occurring during the opening and closing of the valve throughout the cardiac cycle include:

  • Pressure increase during isovolumetric contraction
  • Passive opening of the leaflets
  • Formation of vortex flows within the sinus pockets
  • Maintenance of open coronary artery openings
  • Closure of the leaflets toward the center during relaxation

During the opening phase, the free edges of the leaflets move toward the vascular lumen but do not adhere to the aortic wall. Circular vortex flows forming within the anatomical space provided by the sinuses of Valsalva keep the leaflets balanced within the aortic lumen. These vortex flows help keep the openings of the right and left main coronary arteries unobstructed even in the middle of contraction, thereby protecting the heart’s own blood supply pathway and generating the flow force that initiates leaflet closure at the end of the ejection phase. When the left ventricle finishes ejecting blood and the heart muscle begins to relax, ventricular pressure falls below aortic pressure. The reverse pressure difference developing in the aortic root, together with the vortex flows within the sinuses, pushes the leaflets toward the center, and closure occurs along the lunula line. This closure allows diastolic blood pressure to be maintained within the vascular system. Since most of the blood supply to the left ventricular muscle occurs when the heart relaxes, the valve remaining leakproof during this phase is vital for nourishing the heart muscle.

What Aortic Valve Diseases Develop Over Time and Why Do They Occur?

The aortic valve, which opens and closes an average of seventy times per minute over many years, may undergo structural or functional deterioration due to aging and mechanical stress. Disruption of its thin, flexible, and avascular leaflet architecture places burdens on left ventricular mechanics that are difficult to compensate for. In clinical practice, these disorders are primarily examined within the spectrum of aortic stenosis, in which the valve cannot open sufficiently, and aortic regurgitation, in which the valve cannot close adequately.

The main etiological factors involved in the development of aortic valve diseases include:

  • Age-related calcific degeneration
  • Congenital two-leaflet (bicuspid) valve morphology
  • Previous rheumatic valve involvement
  • Infective endocarditis (valve infection)
  • Ascending aortic aneurysm and annular dilation

Aortic stenosis, a commonly encountered acquired valve disease in developed and developing societies, is a progressive condition affecting approximately twelve percent of individuals over the age of seventy-five. The underlying disease process generally involves lipid infiltration, chronic tissue inflammation, and active calcium deposition in the leaflets with advancing age, through a process resembling atherosclerosis. In addition, in approximately one to two percent of the population, the valve develops congenitally with two rather than three leaflets, a condition known as a bicuspid valve. The abnormal flow dynamics and mechanical stress occurring in bicuspid valves cause the calcification process to develop ten to fifteen years earlier than in tricuspid valves.

How Does Aortic Valve Stenosis Strain the Heart and What Changes Does It Cause?

The aortic valve opening, normally approximately three to four square centimeters under physiological conditions, gradually narrows as calcification progresses. When this opening falls below one square centimeter, considered the critical threshold, the outflow of blood from the left ventricle becomes significantly obstructed. To compensate for this increasing burden and maintain wall tension during contraction, the left ventricular muscle thickens, a condition known as concentric hypertrophy. The heart must contract much more forcefully to push blood through the narrowed opening.

The structural and functional changes occurring in the left ventricle as stenosis progresses include:

  • Concentric thickening of the heart muscle walls
  • Increased connective tissue (fibrosis) between muscle fibers
  • Impairment of left ventricular elasticity and relaxation
  • Reduced microvascular blood supply to the inner layers of the heart muscle
  • Development of systolic and diastolic heart failure

Although this muscle thickening initially helps the heart maintain its pumping function, it produces unfavorable consequences over time. The increase in stiff connective tissue between heart muscle fibers reduces the elasticity of the left ventricle, leading to impaired relaxation (diastolic dysfunction). Subsequently, as capillary blood flow becomes insufficient to nourish the thickened muscle, oxygen deprivation begins in the inner layers of the heart. If this process remains untreated, heart failure develops, accompanied by a weakening of the heart muscle’s contractile strength.

What Is Aortic Valve Regurgitation and How Does It Place a Burden on the Heart?

Aortic valve regurgitation is the backward flow of blood from the aorta into the left ventricle because the leaflets cannot meet edge to edge and close sufficiently during the relaxation phase of the heart. This condition may result from diseases directly affecting the leaflets themselves or from separation of the leaflets due to dilation of the aortic root and ascending aorta to which the valve is attached.

The main clinical conditions that may cause aortic regurgitation include:

  • Age-related leaflet prolapse
  • Rheumatic valve involvement
  • Leaflet perforations caused by infective endocarditis
  • Dilation of the sinotubular junction and annulus
  • Ascending aortic aneurysms

In aortic regurgitation, the left ventricle must accommodate both the normal volume of blood arriving from the left atrium and the amount of blood leaking backward from the aorta during every cardiac cycle. This creates both volume and pressure overload in the left ventricle, causing outward enlargement of the heart muscle (eccentric hypertrophy) and progressive dilation of the ventricular cavity. Although the clinical condition may initially progress without symptoms, left ventricular dilation in advanced stages weakens the contractile ability of the heart muscle, creating the conditions for pronounced signs of heart failure.

What Are the Main Symptoms of Progressive Aortic Valve Diseases?

Aortic valve diseases may have a compensatory phase lasting many years without symptoms. The heart muscle attempts to compensate for the developing stenosis or leakage using its own reserves, and the individual may not experience any noticeable limitations in daily life. However, when the heart’s compensatory mechanisms reach their limits, clinical symptoms appear that reduce patients’ quality of life and indicate the severity of the disease.

The main symptoms of valve disease requiring medical consultation include:

  • Shortness of breath during exertion (dyspnea)
  • Chest pain and a sensation of pressure (angina pectoris)
  • Dizziness and fainting during exertion (syncope)
  • Rapid fatigue during daily activities
  • Heart palpitations and rhythm irregularities
  • Swelling in the legs and abdomen in advanced stages

The course of the disease deteriorates rapidly, particularly with the appearance of the classic triad of symptoms consisting of chest pain, fainting, and shortness of breath during exertion. After symptoms appear, the annual life-threatening risk in critical stenosis cases that are not treated interventionally or surgically ranges between thirty-eight and fifty percent, and the risk of sudden cardiac events increases significantly. Therefore, noticing any of these complaints requires a comprehensive cardiological evaluation without delay.

Which Imaging Methods Are Used in the Diagnosis of Aortic Valve Diseases and Procedure Planning?

Interventional cardiologists use multimodal imaging techniques together to diagnose aortic valve disorders, determine their severity, and assess anatomical suitability for catheter-based treatments. Transthoracic echocardiography (TTE) is the primary examination method for the diagnosis, grading, and follow-up of valve stenosis and regurgitation. Blood flow velocities and pressure gradients obtained through Doppler analysis are evaluated together with the calculated valve area. A valve area below one square centimeter, a flow velocity exceeding four meters per second, or a mean pressure gradient of forty millimeters of mercury or higher indicates severe stenosis.

The main imaging methods and measurement parameters evaluated during diagnosis and preprocedural planning include:

  • Transthoracic echocardiography (TTE)
  • Dobutamine stress echocardiography (DSE)
  • Computed tomography valve calcium score
  • Multislice computed tomography (MSCT) angiography
  • Distance between the annulus and the coronary artery ostium
  • Membranous septum length
  • Diameter mapping of the femoral and abdominal vessels

In clinical practice, a discrepancy between the valve area and measured pressure gradients is detected in approximately forty percent of patients. Particularly in low-flow, low-gradient stenosis cases where the stroke volume index falls below thirty-five milliliters per square meter and the heart’s pumping capacity (ejection fraction) decreases below fifty percent, dobutamine stress echocardiography is performed to distinguish whether the left ventricle has true stenosis or insufficient valve opening due to weakened heart muscle. An increase in stroke volume of twenty percent or more during the stress test confirms the heart’s contractile reserve; at this stage, a valve area remaining at one square centimeter or less together with an increase in the mean pressure gradient to forty millimeters of mercury indicates true severe stenosis. In cases with limited flow reserve or low flow caused by a small ventricular cavity despite preserved pumping capacity, calcium scoring is performed using non-contrast cardiac computed tomography; calcium scores of one thousand two hundred units or higher in women and two thousand units or higher in men confirm the severity of stenosis.

Before transcatheter valve replacement (TAVI), multislice computed tomography angiography is the interventional cardiologist’s most important anatomical roadmap. Since the valve annulus has an elliptical shape, two-dimensional ultrasound measurements may underestimate its diameter. Computed tomography allows the circumference and area of the annulus to be calculated in three dimensions so that an appropriately sized prosthetic valve can be selected; this approach reduces both paravalvular leakage due to inadequate anchoring and the risk of annular rupture that may result from selecting an excessively large valve. In addition, the height of the coronary artery openings above the annulus (generally considered safer when above ten to fourteen millimeters), the dimensions of the sinuses of Valsalva, and the length of the membranous septum are measured to estimate the risks of coronary obstruction and conduction block during the procedure in advance. The diameter, degree of calcification, and tortuosity of the femoral arteries are also mapped using this tomography to ensure safe advancement of catheter sheaths.

How Is Transcatheter Aortic Valve Implantation (TAVI) Performed in Interventional Cardiology?

Transcatheter aortic valve implantation (TAVI) is a procedure in which a stent-based bioprosthetic valve is placed inside the worn and calcified native valve by reaching the heart, most commonly through the femoral artery, without cutting the breastbone or stopping the heart. In interventional cardiology practice, the procedure is generally performed without general anesthesia, using local anesthesia and conscious sedation (a light sleep-like state).

The main procedural steps and systems used in TAVI include:

  • Percutaneous access through the femoral artery (transfemoral approach)
  • Passing the guidewire through the narrowed valve
  • Balloon predilation (valvuloplasty) when necessary
  • Balloon-expandable cobalt-chromium bioprosthetic valves
  • Self-expanding bioprosthetic valves with nitinol frames
  • Rapid cardiac pacing through a temporary pacemaker (rapid pacing)
  • Sutureless percutaneous vascular closure devices

During the procedure, a special sheath is first inserted through the femoral artery using a needle, and a guidewire is passed through the calcified valve to reach the apex of the left ventricle. In anatomically appropriate cases, balloon predilation is performed to stretch the calcified leaflets and facilitate passage of the prosthesis. Two different bioprosthetic valve technologies are mainly preferred for implantation. The first, balloon-expandable valves, consist of bovine pericardial tissue mounted on a cobalt-chromium frame and are deployed by inflating a balloon at the calcified annular plane. To prevent valve displacement during expansion, rapid pacing at one hundred eighty to two hundred beats per minute is applied through a temporary pacemaker wire, reducing blood pumping for several seconds. The second group, self-expanding valves, has a nitinol frame architecture that takes shape at body temperature. These systems allow controlled deployment; if the implantation depth or positioning is considered unsuitable angiographically, the valve can be recaptured before final release and repositioned. The new prosthetic valve is secured by pressing the calcified native leaflets toward the aortic wall and begins functioning immediately. At the end of the procedure, coronary artery patency, pressure gradient, and paravalvular leakage are checked using control angiography and echocardiography; the femoral access site is closed with specialized vascular closure devices without requiring sutures.

What Are Balloon Valvuloplasty, Valve-in-Valve, and Leak Closure Procedures for Aortic Valve Problems?

In interventional cardiology, catheter-based methods are not limited to patients undergoing TAVI for the first time; different catheter techniques are also used in emergency situations and for patients who have previously undergone procedures. One of these techniques, aortic balloon valvuloplasty, involves inflating appropriately sized catheter balloons introduced through the femoral artery to fracture leaflet calcifications and temporarily enlarge the narrowed valve opening. Due to elastic recoil of the valve and continued calcium accumulation, stenosis generally recurs within six to twelve months after the procedure; therefore, it is not a permanent treatment. However, it is performed as a bridging procedure to reduce the burden on the left ventricle in critically ill patients presenting to the emergency department in shock, to support surgical safety in patients with critical stenosis who require emergency noncardiac surgery, or to stabilize the patient before TAVI.

In patients who previously received a surgically implanted bioprosthetic valve or underwent TAVI in earlier years, valve stenosis or regurgitation may recur when the bioprosthetic tissue reaches the end of its functional lifespan. Reopening the chest in this patient group carries a high surgical risk. Using catheter techniques, interventional cardiologists place a new TAVI valve directly inside the deteriorated previous surgical or transcatheter bioprosthesis (Valve-in-Valve), thereby protecting the patient from the risks of a second open operation and restoring valve function.

Furthermore, after surgical valve replacement or TAVI, small gaps may remain between the frame of the prosthetic valve and the patient’s natural tissue due to the pattern of calcification. These peripheral leaks, called paravalvular leaks, may cause volume overload in the left ventricle and anemia (hemolytic anemia) resulting from the destruction of red blood cells passing through narrow gaps. In the interventional cardiology laboratory, the leakage pathway can be reached using catheters, and specialized vascular plug devices can be placed to control these leaks through a minimally invasive approach without requiring open surgery.

What Are the Differences Between Catheter-Based Aortic Valve Treatments and Open Surgical Methods?

The choice between surgical aortic valve replacement (SAVR) and catheter-based TAVI for aortic valve diseases is determined by a multidisciplinary Heart Team, taking into consideration the patient’s age, surgical risk scores, anatomical suitability, and accompanying diseases, in accordance with the guidelines of the Turkish Society of Cardiology and the European Society of Cardiology. Generally, TAVI is considered a priority for patients aged seventy-five and older and individuals with moderate or high surgical risk, while open surgical options are emphasized for younger patients with low surgical risk.

The main advantages of the TAVI approach offered by interventional cardiology compared with open surgery include:

  • No cutting of the breastbone (no sternotomy)
  • No need for connection to a heart-lung machine
  • Performing the procedure on a beating heart with physiological circulation maintained
  • Local anesthesia and sedation being sufficient in most cases
  • Reduced pulmonary risks associated with mechanical ventilation (intubation)
  • Possibility of hospital discharge within two to four days
  • Early mobilization and walking within the first twenty-four hours

Open-heart surgery requires cutting the breastbone, stopping the heart and connecting it to a heart-lung machine, and inserting a breathing tube under general anesthesia. The average hospital stay, including intensive care, is seven to ten days, while bone healing involves a recovery period of six to twelve weeks. The TAVI approach, however, eliminates the need for bone cutting and the systemic inflammatory response triggered by the heart-lung machine. Not stopping the heart limits the risk of heart muscle injury during the procedure. Avoiding a breathing tube significantly reduces pulmonary complications, particularly in individuals with chronic obstructive pulmonary disease (COPD), limited respiratory capacity, and advanced age-related frailty. Early mobilization helps patients return to their daily lives quickly while reducing hospitalization-related problems such as muscle wasting and hospital-acquired infections.

Of course, like every advanced cardiovascular intervention, TAVI has its own anatomical risks, which are managed through detailed preprocedural planning. If the prosthetic valve is implanted too deeply into the left ventricular outflow tract, pressure may develop on the conduction fibers within the membranous septum, potentially requiring permanent pacemaker implantation in six to sixteen percent of cases. Interventional cardiologists seek to reduce this risk by deploying the valve in a higher position, closer to the annular plane, based on tomographic measurements of the membranous septum and by using repositionable valve systems. The risk of paravalvular leakage is largely controlled through outer sealing skirts added around new-generation valves and balloon post-dilation maneuvers at the end of the procedure. Evaluation by an interventional cardiology specialist, supported by echocardiographic and tomographic examinations, allows individuals experiencing symptoms of valve disease, such as chest pain, rapid fatigue, shortness of breath, or fainting, to determine the catheter-based treatment method suitable for them without requiring open surgery and to protect their heart health through a more comfortable approach.